Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
This is a good quality scan of the Operation & Maintenance (Service) Manual for the PAL version of this high-band broadcast umatic, BVU-800P
All schematics and lineup procedures appear to be included in this one manual AFAICT.
The file size is just over 113 MB which gives an idea of the quality and number of pages.
All of the schematics, which contain some fairly small print, are easily readable when you zoom into the page.
John Thompson, Newcastle Upon Tyne, England.
 ;
Good quality, all schematics of few of models. There is also short form of user manual and regulation manual.
 ;
Perfect copy of the service manual. you can enlarge every page, and it comes up
with all details.
 ;
It´s very very nice manual with all, what i need. Original in good quality. Very fast business. Very much thanks...
 ;
Purchased the manual that I was looking for at a great price and could download it easily.. Great service experience and for future purchases I plan to use the site.
Thank you very much
HOW TO TAKE OUT FRONT GRILLE Please follow below steps to take out front grille if necessary such as when servicing. Remove the Grille from the chassis. 1. Set the up-and-down air direction louver to open position (horizontally) by finger pressure.
10.3. OUTDOOR UNIT
10.3.1. SELECT THE BEST LOCATION (Refer to �Select the best location� section) 10.3.2. INSTALL THE OUTDOOR UNIT
2. Open the three screw covers as shown in the illustration below.
� After selecting the best location, start installation according to Indoor/Outdoor Unit Installation Diagram. 1. Fix the unit on concrete or rigid frame firmly and horizontally by bolt nut. (ø10 mm). 2. When installing at roof, please consider strong wind and earthquake. Please fasten the installation stand firmly with bolt or nails.
3. Remove the five mounting screws. 4. Open the front panel and remove a mounting screw at the centre. (Refer Diagram below) 5. To remove the Grille, pull the lower left and right side of the grille towards you (slightly tilted) and lift it straight upwards (Two tabs on the top inside edge of the grille are clear of their slots).
10.3.3. CONNECTING THE PIPING
Connect Piping to Indoor Please make flare after inserting flare nut (locate at joint portion of tube assembly) onto the copper pipe. (In case of using long piping) Connect the piping � Align the center of piping and sufficiently tighten the flare nut with fingers. � Further tighten the flare nut with torque wrench in specified torque as stated in the table.
REMOTE CONTROL NO. SWITCH 1. When installing two air conditioners in one room, each air conditioner can be synchronized to the remote controller. 2. In order to operate separately, open the rear cover of one of the remote controller and set the switch to �B�. 3. Also, set the remote control No. switch to �B� in the corresponding indoor unit. (The switch is located in the control box-sub. of the indoor unit.) Connect the Piping to Outdoor Unit 1. Align the center of the piping and sufficiently tighten the flare nut with fingers. 2. Finally, tighten the flare nut with torque wrench until the wrench clicks. � When tightening the flare nut with torque wrench, ensure the direction for tightening follows the arrow on the wrench.
|
|
 |
> |
|